# What is Connected Load?

- Link: https://studyelectrical.com/2021/09/what-is-connected-load.html
- Published: 2021-09-10T06:34:42+00:00
- Author: Tesla

## Definition

The connected load is the sum of the continuous ratings of all the equipment connected
to the supply system.

In other words, the connected load is the sum of all the nameplate ratings of the
equipment within the consumer installation.

Connected load represents the maximum possible energy consumption when all connected
systems, circuits, components, devices, or equipment are simultaneously operating
and drawing power. Think of it as the “worst-case scenario” when every electrical
item is switched on and demanding electricity simultaneously.

For instance, in a household, the connected load would encompass the collective 
power requirements of all electrical appliances and devices, including lights, air
conditioners, refrigerators, and more, assuming they are all running concurrently
at their maximum capacity. In a manufacturing plant, it would include all machines
and equipment running at full tilt.

Connected Load is essential for sizing electrical infrastructure, such as [wiring](https://studyelectrical.com/2015/05/systems-of-wiring-introduction-to-electricl-wiring.html),
[circuit breakers](https://studyelectrical.com/2014/05/classification-types-of-circuit-breakers.html),
[transformers](https://studyelectrical.com/2015/04/working-principle-of-transformer.html),
and [generators](https://studyelectrical.com/2015/12/working-principle-of-alternator.html).
It helps ensure that the electrical system can handle the peak power demands without
overloading or causing safety issues.

## Calculation of Connected Load

Here is an example to illustrate what is the connected load on a power station and
how it is calculated. Consider a power station supplying loads to 1000 consumers.
In every consumer’s home, there is certain equipment installed. “Connected load”
of a consumer is the sum of the continuous ratings of all the equipment of the consumer’s
premises.

For example, if each consumer of the power station has the following connections

 * Five 100-watt lamps
 * Two 60 watt fans
 * Power socket point of 500 watts

Then the CL of one consumer is 5×100 + 2×60 + 500 = 1120 watts.

This is the **Connected Load of one consumer**. Similarly, every consumer has their
own connected load depending on the electrical equipment used in their house.

When you add up the CL of all the consumers, you get the **connected load for the
power station**.

Connected Load for the power station = 1120 × 1000 = 1120000 W = 1120 kW.

## Connected Load vs Demand Load

Electrical load, in simple terms, refers to the total energy consumed by various
components, devices, or equipment connected to a power source. It can be further
divided into two: **Connected Load and Operating Demand Load**. These distinctions
play a crucial role in efficient power management for both residential and industrial
applications.

**Connected Load** is the energy consumed when all connected systems, circuits, 
components,
devices or equipment are operating and drawing power at the same time.

While Connected Load provides a critical perspective on the electrical infrastructure’s
capacity requirements, it often paints an unrealistic picture of everyday energy
consumption. In practice, not all electrical devices and equipment operate simultaneously
at their maximum capacity. This is where Operating Demand Load comes into play.

**Operating Demand Load** represents a more practical and accurate estimation of
energy consumption. It takes into account the likely simultaneous operation of electrical
items based on real-world usage patterns. For example, in a home, it acknowledges
that the furnace and air conditioning unit are unlikely to run simultaneously, as
they serve opposing purposes in different seasons. Therefore, when calculating the
Operating Demand Load, these two items are not added together.

In an industrial setting, Operating Demand Load considers the specific production
processes, shifts, and operational schedules. It ensures that the electrical infrastructure
is designed to meet the actual demands placed on it during regular operations, minimizing
wasted energy and resources.

## Maximum Demand

The **maximum demand** often referred to as** peak demand** can be found in the[ load curve](https://studyelectrical.com/2016/03/load-curve-in-power-plant-daily-annual.html)
is defined as the greatest of all the demands which have occurred in the power station
during a given period.

The figure below shows the maximum demand in a daily load curve.

![Daily Load curve on Power Plant](https://studyelectrical.com/wp-content/uploads/
2016/03/Daily-Load-curve-on-Power-Plant.jpg)

Daily Load curve on Power Plant

The power plant supplies power to all the loads connected to it. This does not necessarily
mean that they will all receive power together. For example, you might switch off
the lighting loads during the daytime. During the night, certain factory loads might
be disconnected. Occasionally, some motors will turn on and off. When the long travel
motor of the crane is running, the [hoist motor](https://rmhoist.com/about-us/blog/how-does-a-hoist-work)
is switched off. Therefore, in practice, the total load on at any one time is less
than the total connected load.

**Example**:

Imagine you were an electric company serving 1000 homes with only a 3000 watt electric
oven in each house. Your connected load would be 3,000,000 watts.

In reality, there may never be a time when all homes use heaters at the same time.
Let’s say that only 500 homes use heaters all at the same time. The reason for this
is what we call load diversity, or load factor. This would result in a demand load(
maximum demand) of 1,500,000 watts. In that case, you only need to design your system
for half the value of the connected load.

Many high-wattage appliances (such as toasters) have a very low load factor. Other
appliances (electric heat) can have very large load factors at times (in very cold
weather).

Ultimately, there are a great variety of appliance types, each with its own load
factor, and the utility has to worry about only the aggregate of ALL connected loads.

## Demand Factor

Demand Factor is the ratio of maximum demand on the power station to its connected
load.

**Demand factor = Maximum demand/Connected load **

The value of the demand factor is usually less than 1. It is expected because the
maximum demand (peak load) on the power station is generally less than the CL.

If the maximum demand on the power station is 80 MW and the connected load is 100
MW, then the demand factor = 80/100 = 0·8.

The knowledge of the demand factor is vital in determining the capacity of the plant
equipment.

### Related posts:

 [ ⌊aeolian vibration⌉Aeolian Vibration of Transmission Conductors](https://studyelectrical.com/2019/07/aeolian-vibration-of-transmission-conductors.html)
[ ⌊Transformer Percentage Impedance Testing⌉How to Test Percentage Impedance of Transformer?](https://studyelectrical.com/2019/08/how-to-test-percentage-impedance-of-transformer.html)
[ ⌊Electrical Engineering Basics - The ultimate guide⌉Electrical Engineering Basics: The Ultimate Guide](https://studyelectrical.com/2019/10/electrical-engineering-basics.html)
[ ⌊How to rescue a person from electric shock⌉How to Rescue a Person from Electric Shock?](https://studyelectrical.com/2019/11/how-to-rescue-a-person-from-electric-shock.html)
[ ⌊Titanium in clean energy production⌉How Titanium Can Contribute To Clean Energy Production](https://studyelectrical.com/2022/04/how-titanium-can-contribute-to-clean-energy-production.html)
[ ⌊Equivalent Circuit for Tan δ Measurement and Phasor Diagram⌉Tan Delta Test | Loss Angle Test | Dissipation Factor Test](https://studyelectrical.com/2023/05/tan-delta-test-loss-angle-test-dissipation-factor-test.html)
[ ⌊EICR Guide 1⌉What is an EICR: Essential Guide to Electrical Installation Condition Reports](https://studyelectrical.com/2023/05/eicr-guide-electrical-installation-condition-reports.html)
[ ⌊Load break switch with SF6 interrupters⌉Load Break Switches in Electrical Substations](https://studyelectrical.com/2023/08/load-break-switches.html)
[ ⌊High Speed Grounding Switches⌉High Speed Grounding Switches](https://studyelectrical.com/2023/09/high-speed-grounding-switches.html)
[ ⌊lightning rod⌉How Does Lightning Rods Work?](https://studyelectrical.com/2023/09/how-does-lightning-rods-work.html)

## Comments

### By: Mayra

- Link: https://studyelectrical.com/2021/09/what-is-connected-load.html#comment-6329
- Published: 2021-09-28T12:15:40+00:00

This article is a great tool for useful information about something new. This article
provided a great information about connected load. This article will help you if
you are looking for something new.

### By: Rajesh

- Link: https://studyelectrical.com/2021/09/what-is-connected-load.html#comment-6510
- Published: 2021-10-20T14:41:49+00:00

nice post

### By: James

- Link: https://studyelectrical.com/2021/09/what-is-connected-load.html#comment-6648
- Published: 2021-11-08T06:28:26+00:00

Nice explanation. Thank you

### By: Syllablecounter

- Link: https://studyelectrical.com/2021/09/what-is-connected-load.html#comment-24120
- Published: 2023-10-19T19:50:55+00:00

This post provides an interesting perspective on the topic of connected load and
how it can impact our daily lives. It’s informative to learn about this concept 
and its implications, especially in today’s world where technology plays such a 
significant role in our lives.
