  • DC Ammeter : Construction, Working and Temperature Compensation

DC Ammeter : Construction, Working and Temperature Compensation

  • Categories Measurement, Electronics
DC Ammeter Construction Diagram 1

Table of Contents

  • What is DC Ammeter?
  • Construction of DC Ammeter
  • DC Ammeter Calculations
    • Temperature compensation

What is DC Ammeter?

A DC ammeter is the instrument used for measuring the direct current (DC) flowing through an electrical circuit and is connected in series to the circuit under consideration.


DC Ammeter Symbol
DC Ammeter Symbol

Construction of DC Ammeter

The construction of DC ammeter is similar to a galvanometer. The instrument has an internal resistance which should be much smaller in comparison to the resistance of the circuit. The basic movement of a DC ammeter is constituted by a PMMC d’Arsonval galvanometer. Thus, the basic construction of the DC ammeter remains the same as galvanometer.

Construction of a DC Ammeter
Construction of a DC Ammeter is same as of a d’Arsonal Galvanometer

The deflection of the pointer is in proportion to the current flowing in the moving coil.

Here, the maximum deflection of the pointer is produced by a very small current as the coil winding is very light and thin.

The large currents may destroy the coil winding. Therefore, to measure such large currents, the ammeter is provided with a resistor of very low resistance (generally less than 1 Ohm) and referred to as shunt connected in parallel to the instrument coil or meter movement. The shunt may be external or internal to the instrument.

The external shunt is made up of manganin or constantan.

The external shunt is made up of manganin or constantan with the low resistance. Whereas the internal shunt used with the basic movement is in the form of a constant temperature resistance wire encased within the instrument. However, more often external shunts are used to measure large currents.

When a large amount of current is to be measured, the major part of it must be bypassed via the shunt so that the dc ammeter does not get damaged.

DC Ammeter Calculations

The basic configuration of an ammeter circuit is shown below.

Basic DC Ammeter Circuit
Basic DC Ammeter Circuit

Here, Rsh represents shunt resistance and Rm is meter resistance (also known as coil circuit resistance or internal resistance of the movement)

From the figure above, we can say that the total current I is bifurcated into the meter current Im (also termed as full scale deflection current of the movement IFSD ) and shunt current Ish , such that, on summing the total current I is I = Im + Ish

Total Current, I = Im + Ish

It necessitates that the voltage drop across the movement and the shunt must be the same. Thus, the required shunt resistance Rsh can be calculated.

dc ammeter calculation

Since, [latex] V_{s h}=V_{m} [/latex]

[latex] I_{s h} R_{s h}=I_{m} R_{m} [/latex]

⇒ [latex] R_{s h}=\frac{I_{m} R_{m}}{I_{s h}} [/latex] (Eqn 1)

Here, we know that: [latex] I_{s h}=I-I_{m}[/latex]

Substituting the value of Ish from into Eqn (1), we get:

[latex]R_{s h}=\frac{I_{m} R_{m}}{I-I_{m}}[/latex]

Given the values of total current I, meter current Im , and meter resistance Rm , the value of shunt resistance Rsh can be calculated using the relation the equation. Further, the above relation can be modified as:

[latex]\frac{R_{s h}}{R_{m}}=\frac{I_{m}}{I-I_{m}} & \text { or } \quad \frac{R_{m}}{R_{s h}}=\frac{I-I_{m}}{I_{m}} [/latex]

[latex]\frac{R_{m}}{R_{s h}}=\frac{I}{I_{m}}-1 & \text { or } \quad \frac{I}{I_{m}}=\frac{R_{m}}{R_{s h}}+1[/latex]

Here, term I/Im represents the multiplying power of the shunt and is denoted by m.

Thus, equation can be written as:

[latex]m=\frac{R_{m}}{R_{s h}}+1 [/latex]

[latex]R_{s h}=\frac{R_{m}}{m-1}[/latex]

This equation is used to determine the shunt resistance of the circuit when the multiplying power of the shunt is known.

Note that if shunt resistance Rsh is 1 ohm and meter resistance Rm is exactly 99 ohm and the meter shows full scale deflection for a coil current Im = 0.1 mA.

Then, the scale should be calibrated as 100 × 0.1 mA = 10 mA to read at full scale.

Temperature compensation

The moving coil in a PMMC instrument is wound with thin copper wire whose resistance changes with change in temperature.

The errors are introduced in current measurements due to heating effect of the coil current which produces resistance change.

The swamping resistance is a resistor with zero temperature coefficient, put in series with the meter movement in an ammeter circuit.

A swamping resistance made of manganin or constantan with negligible temperature coefficient having resistance 20 to 30 times the coil resistance is connected in series with the coil and shunt resistance made of manganin is connected in parallel to the combination in order to avoid resistance changes with temperature.

DC ammeter temperature compensation using swamping resistor
DC ammeter temperature compensation using swamping resistor

Therefore, the current I flowing through the circuit divides in proportion between the meter and the shunt which does not change appreciably with change in temperature.

  • Share:
Admin bar avatar
Tesla Edison
Tesla is an Electrical Engineer, Physicist and an Inventor in making. He is a good writer and author of many courses and articles published in this site.

Previous post

Electrolytic Capacitor - Types, Construction, Polarity and Leakage Current
August 8, 2020

Next post

What is Shunt Capacitor Bank? 4 SCB Configurations
September 1, 2020

Leave A Reply Cancel reply

Your email address will not be published. Required fields are marked *

Get Your Password

Lost your password? Please enter your username or email address. You will receive a link to create a new password via email.

Recent Articles

  • Going Beyond Theory And Books: High-performance Liquid Chromatography
  • How to Select an Electronic Contract Manufacturing Partner
  • 7 FE Electrical and Computer Practice Problems with Solutions
  • Sinusoids and Phasors
  • 2 Important Distribution Transformer Testing Methods
For Advertisements Contact
[email protected]

Copyright © 2020 Study Electrical, Inc.

© StudyElectrical.Com 2020

Connect with

Login with Facebook Login with Google Login with LinkedIn

logo

Login with your site account

Connect with

FacebookGoogleLinkedIn

logo


Lost your password?

Not a member yet? Register now

Register a new account

Connect with

FacebookGoogleLinkedIn

logo


Are you a member? Login now