# Square D QO Circuit Breakers

- Link: https://studyelectrical.com/2019/02/square-d-qo-circuit-breakers.html
- Published: 2019-02-03T10:35:48+00:00
- Author: Tesla

![Square D Circuit Breaker](https://studyelectrical.com/wp-content/uploads/2019/
02/Square-D-Circuit-Breaker.jpg)

QO stands for Qwik-Open. Square D QO Circuit Breakers are fastest tripping circuit
breakers at 1/60th of a second.

QO™ Circuit Breakers provide the high level of protection you expect from Square
D. When it comes to electrical protection, fast response is critical and QO™ Circuit
Breakers can trip faster than the blink of an eye.

The exclusive QO™ Visi-Trip™ instantly identifies a tripped [circuit breaker](https://studyelectrical.com/2018/12/circuit-breaker-operating-principle-and.html)
with a red indicator window. When a QO™ Visi-Trip™ circuit breaker trips, the handle
snaps to a midpoint position between “OFF” and “ON” and a highly visible, red indicator
easily identifies the tripped breaker. The Visi-Trip™ reduces the number of callbacks,
as well as the chance that other circuits will be turned off accidentally.

### QO Circuit Breaker Features

 * Limited lifetime warranty
 * Exclusive Visi-Trip™ red indicator.
 * Plug-on design, easy to install.
 * Quick make – quick break mechanism.
 * Trip reaction within 1/60th of a second.
 * Single Pole 15 A and 20 A breakers are Switching Duty Rated (SWD).
 * SWD – Suitable for switching 120 Vac [fluorescent lighting](https://studyelectrical.com/2014/05/how-fluorescent-tube-lights-work.html)
   loads.
 * Option for padlocking breaker in “ON” or “OFF” position.
 * Slot/Robertson screws for wire termination.
 * HACR type for use with air conditioning, heating and refrigeration equipment 
   having motor group combinations and marked for use with HACR type circuit breakers.(
   Except for QO2100)

## Circuit Breaker Product Selection Guide

### Plug-On Circuit Breakers Selection – 10,000 AIR

![Plug-On Circuit Breakers Selection - 10,000 AIR](https://studyelectrical.com/wp-
content/uploads/2019/02/Plug-On-Circuit-Breakers-Selection-10000-AIR.jpg)

Plug-On Circuit Breakers Selection – 10,000 AIR

#### High Magnetic Breakers Selection

High magnetic breakers are recommended for applications where high initial inrush
current may occur.

![High Magnetic Breakers Selection](https://studyelectrical.com/wp-content/uploads/
2019/02/High-Magnetic-Breakers-Selection.jpg)

High Magnetic Breakers Selection

### Tandem (Space Saver) Circuit Breakers Selection – 10,000 AIR

Tandem (Space Save) circuit breakers are ideal for adding additional circuits to
an existing panel with limited space.

![Tandem (Space Saver) Circuit Breakers Selection - 10,000 AIR](https://studyelectrical.
com/wp-content/uploads/2019/02/Tandem-Space-Saver-Circuit-Breakers-Selection-10000-
AIR.jpg)

Tandem (Space Saver) Circuit Breakers Selection – 10,000 AIR

## QO Ground Fault Circuit Breakers

QO™ Ground Fault Circuit Interrupters (GFCIs) combine the same level of overcurrent
circuit protection as standard QO™Circuit Breakers, with ground fault protection
for personal protection against [electrical shock](https://studyelectrical.com/2014/10/effect-of-electric-current-on-human.html).

GFCI protection is required in wet or damp areas such as bathrooms, kitchens, garages,
spas, pools and outdoor receptacles. Do not connect to more than 250 feet of load
conductor for the total one-way run to prevent nuisance tripping.

### QO Ground Fault Circuit Breaker Features

 * Provides overload and short circuit protection combined with Class A ground fault
   protection.
 * Class A denotes a ground fault that will trip when a fault current to ground 
   is 5 milliamperes or more for people protection.
 * Exclusive Visi-Trip™ red indicator.
 * Yellow push to test button.
 * Provides an option for the padlock in “ON” or “OFF” position

## QO Combination Arc Fault Circuit Breakers

Beginning in 2015, the Canadian Electrical code will require the use of Combination
Arc Fault Circuit Interrupters
 (CAFCIs) in each branch circuit suppling 125V receptacles
rated 20A or less (except in the kitchen, bathrooms, sump pump).

Square D CAFI breakers are available in both pigtail and plug-on (pigtail less) 
formats, 1 pole/2 pole, and
 15A/20A versions.

### Square D Combination Arc Fault Circuit Breaker Features

 * Detects unintended arc faults, overloads and short circuits.
 * White push to test button.
 * Exclusive Visi-Trip™ red indicator.
 * Plug-on CAFCI version helps minimize installation time by reducing the number
   of runs and wires. Results in cleaner and faster wiring. Ideal for inspection.
 * The Plug-on CAFCI breaker can only be installed in Square D Plug-on neutral ready
   loadcentre.
 * Saves time – equipped with TIME SAVER diagnostics feature that assists in identifying
   the type of fault in a circuit.

## TIME SAVER Diagnostics

All Square D QO combination arc fault circuit breakers come with a TIME SAVER diagnostics
feature that assists in identifying the type of fault that has occurred when the
breaker has tripped.

 * Requires no tools – easy to use.
 * Saves money and time.
 * How to use: turn off the circuit breaker, HOLD DOWN the Push-to-test button, 
   and then turn the circuit breaker back on.
 * Use the chart below to determine fault.

[table id=1 /]

## QO Dual Function Circuit Breakers

Square D Dual Function circuit breakers combine combination arc fault and ground
fault protection in a single device.

The dual function circuit breaker meets the 2015 Canadian Electrical code requirements
for combination arc fault protection in the home, while also offering (Class A –
people protection) ground fault protection.

This unique combination saves space in the panel and installation time for the homeowner
or contractor, replacing the arc fault breaker and a ground fault receptacle combination.

Ideal for the bedroom and bathroom, where one dual function breaker can arc fault
protect the bedroom and ground fault the en suite bathroom.

Another application is an outdoor receptacle where the dual function breaker can
provide arc fault and ground fault protection inside the home instead of exposed
to the outdoor weather.

With the built in TIME SAVER diagnostics feature, trouble shooting a fault is easier
and faster

### Square D Dual Function Circuit Breaker Features

 * Detects unintended arc faults, ground faults, overloads and short circuits.
 * Purple push to test button.
 * Exclusive Visi-Trip™ red indicator.
 * Offered in both pigtail and non pigtail versions.
 * Plug-on version helps minimize installation time by reducing the number of runs
   and wires, ideal for inspection.
 * Saves time – equipped with TIME SAVER diagnostics feature that assists in identifying
   the type of fault in a circuit.

## QO Main Circuit Breakers

QO™ Main breakers are bolt-on for all residential service entrance loadcentres. 
Standard 22,000/10,000 ampere series short circuit current rating on main breaker
panels provides increased application capability.

### Features

 * Provides option for padlock in “OFF” position.
 * Bolt-on main breaker for Square D service entrance panels

Reference: [https://images.atgstores.com/pdf/13154/047569008986_ca_meas.pdf](https://images.atgstores.com/pdf/13154/047569008986_ca_meas.pdf)

### Related posts:

 [ ⌊Default Thumbnail⌉MCB (Miniature Circuit Breakers) – Types, Working and Trip Curves](https://studyelectrical.com/2014/07/miniature-circuit-breakers-mcb-types-characteristic-curves.html)
[ ⌊Auto Reclosing principle⌉Auto Reclosing of Power Lines and Types of Faults](https://studyelectrical.com/2019/02/auto-reclosing-of-power-lines.html)
[ ⌊Complete Guide on Ground Fault Circuit Interrupters⌉GFCI (Ground Fault Circuit Interrupter) – Working, Types, Installing and Troubleshooting](https://studyelectrical.com/2019/03/gfci-ground-fault-circuit-interrupter-breaker.html)
[ ⌊Principle of core balance protection RCCB working⌉How RCCB/ELCB Protects You from Death?](https://studyelectrical.com/2021/11/how-rccb-elcb-protects-you-from-death.html)
[ ⌊Transmission-switching⌉Why Do We Use Transmission Switching in Electricity Supplies?](https://studyelectrical.com/2022/08/why-transmission-switching-in-electricity-supplies.html)
[ ⌊HRC Fuse⌉Low Voltage Fuses: Types and Examples](https://studyelectrical.com/2023/09/low-voltage-fuses.html)
[ ⌊Generator Reactors⌉Current Limiting Reactor or Series Reactor](https://studyelectrical.com/2023/09/current-limiting-reactor-series.html)
[ ⌊Hydraulic Magnetic Circuit breaker⌉Hydraulic Magnetic Circuit Breaker – Construction, Working and Application](https://studyelectrical.com/2024/03/hydraulic-magnetic-circuit-breaker.html)
[ ⌊what is connected load⌉What is Connected Load?](https://studyelectrical.com/2021/09/what-is-connected-load.html)
[ ⌊Hydrograph⌉Hydrograph: Understanding Components, Types & Applications](https://studyelectrical.com/2025/11/hydrograph-understanding-components-types-applications.html)