# Voltage Surge in Power System

- Link: https://studyelectrical.com/2018/09/voltage-surge-transient-meaning-causes-occur.html
- Published: 2018-09-05T13:33:00+00:00
- Author: 

### What is Voltage Surge or Transient Voltage?

The sudden rise in voltage for a very short duration on power system is known as
voltage surge or transient voltage.

 

Surges or transients can damage, degrade, or destroy electronic equipment within
any home, commercial building, industrial, or manufacturing facility. Transients
can reach amplitudes of tens of thousands of volts.  Surges are generally measured
in microseconds (μs).

### How does Surges Occur?

Transients or surges are of temporary nature and exist for a very short duration(
a few hundred microseconds) but they cause overvoltages on the power system. 

 

They originate from switching and from other causes but by far the most important
transients are those caused by lightning striking a transmission line. When lightning
strikes a line, the surge rushes along the line, just as a flood of water rushes
along a narrow valley when the retaining wall of a reservoir at its head suddenly
gives way. 

 

In most of the cases, such surges may cause the line insulators (near the point 
where lightning has struck) to ﬂash over and may also damage the nearby transformers,
generators or other equipment connected to the line if the equipment is not suitably
protected.

### Lightning Surge

![Voltage Surge Waveform](https://studyelectrical.com/wp-content/uploads/2018/09/
surge-300x175.png)

Voltage Surge Waveform
 Waveform of a typical lightning Surge

The figure above shows the waveform of a typical lightning surge. The voltage build-
up is taken along the y-axis and the time along the x-axis. 

 

It may be seen that lightning introduces a steep-fronted wave. The steeper the wavefront,
the more rapid is the build-up of voltage at any point in the network. In most of
the cases, this build-up is comparatively rapid, being of the order of l-5 μs. 

 

Voltage surges are generally speciﬁed in terms of the rise time t1 and the time 
t2 to decay to half of the peak value. For  example, a 1/50μs surge is one which
reaches its maximum value in 1μs and decays to half of its peak value is 50μs.

### Causes of Surges

60-80% of surges are created within a facility. A common source for surges generated
inside a building are devices that switch power on and off. This can be anything
from a simple thermostat switch operating a heating element to a switch-mode power
supply found on many devices.  Surges that originate from outside the facility include
those due to lightning and utility grid switching. 

### Related posts: