# Types of DC Generator – Series, Shunt and Compound

- Link: https://studyelectrical.com/2014/08/types-of-dc-generators.html
- Published: 2014-08-06T17:59:00+00:00
- Author: 

Please go through the [construction of dc generator](http://www.studyelectrical.com/2014/06/construction-dc-motor-dc-motor-construction.html)
before reading this article about different types of dc generator. 

A DC generator requires MMF to establish flux in its magnetic circuit. The MMF necessary
to establish flux in the magnetic circuit of a dc generator is obtained by field
excitation.

When a DC voltage is applied to the field windings of a DC generator, current flows
through the windings and sets up a steady magnetic field. This is called field excitation.

Field excitation can be obtained by the following means

 * Permanent magnets
 * Field coils excited from some external source and
 * Field coils excited by the generator itself. 

The excitation voltage can be produced by the generator itself or it can be supplied
by an outside source, such as a battery.

If the flux is established using permanent magnets, then this type of dc generator
is called **Permanent magnet dc generator. **

If the flux is obtained by exciting field coils from some external source, that 
type of dc generator is called **Separately excited dc generator. **

If field coils are excited by the generator itself to establish the required flux,
then such type of dc generators are called **Self-excited dc generators.**

Generators are generally classified according to these methods of field excitation.
On this basis, different types of dc generator are divided into the following three
classes:

 1. **Permanent magnet dc generators **
 2. **Separately excited dc generators **
 3. **Self-excited dc generators **
 4.  a. Series Wound dc generator
     b. Shunt Wound dc generator
     c. Compound Wound dc generator

![types of dc generator](https://studyelectrical.com/wp-content/uploads/2014/08/
types-of-dc-generator.jpg)

Types of dc generator

In permanent magnet dc machines, a permanent magnet is used to establish flux in
the magnetic circuit. 

These generators are not found in industrial applications because of the low power
generated from it. Such generators are employed only in small sizes like dynamos
in motorcycles.

The behavior of a dc generator on load depends upon the method of field excitation
adopted.

## Separately Excited D.C. Generators

A dc generator whose **field magnet winding is supplied from an independent external
d.c. source** (e.g., a battery etc.) is called a separately excited generator.

The figure shows the connections of a separately excited generator. The voltage 
output depends upon the speed of rotation of armature and the field current (Eg 
= φZNP/60 A). The greater the speed and field current, the greater is the generated
e.m.f.

It may be noted that separately excited d.c. generators are rarely used in practice.
The d.c. generators are normally of self-excited type. Also, read [characteristics of separately excited dc generator](https://studyelectrical.com/2014/08/characteristics-of-separately-excited-dc-generator.html).

![seperately excited dc generator](https://studyelectrical.com/wp-content/uploads/
2014/08/seperately-excited-dc-generator-1.png)

Seperately excited dc generator

 Armature current, I_(a) = I_(L)_( )

Terminal voltage, V = E_(g) – I_(a)R_(a)_( )

Electric power developed = E_(g)I_(a)_( )

Power delivered to load = E_(g)I_(a) – I R = I E – I R = VI_(a )

## Self-Excited D.C. Generators

A d.c. generator whose **field magnet winding is supplied current from the output
of the generator itself** is called a self-excited generator.

A generator that supplies its own field excitation is called a self-excited generator.
Self-excitation is possible only if the field pole pieces have retained a slight
amount of permanent magnetism, called residual magnetism.

When the generator starts rotating, the weak residual magnetism causes a small voltage
to be generated in the armature. This small voltage applied to the field coils causes
a small field current.

Although small, this field current strengthens the magnetic field and allows the
armature to generate a higher voltage. The higher voltage increases the field strength,
and so on. This process continues until the output voltage reaches the rated output
of the generator.

There are three types of self-excited dc generator depending upon the manner in 
which the field winding is connected to the armature, namely;

 1. **Series generator**
 2. **Shunt generator**
 3. **Compound generator**

### 1. DC Series Generator

In a series-wound generator, **the field winding is connected in series with armature
winding** so that whole armature current flows through the field winding as well
as the load.

The figure shows the connections of a series-wound generator. Since the field winding
carries the whole of load current, it has a few turns of thick wire having low resistance.

Series generators are rarely used except for special purposes e.g., as boosters.

[⌊Series Wound DC Generator⌉⌊Series Wound DC Generator⌉[

Series Wound DC Generator

Armature current, I_(a) = I_(se) = I_(L) = I(say)

 Terminal voltage, V = E_(G) – I(R_(a) + R_(se))

 Power developed in armature = E_(g)I_(a)

A series-wound generator uses **very low resistance field coils**, which consist
of a few turns of large diameter wire. The voltage output increases as the load 
circuit start drawing more current.

Under low-load current conditions, the current that flows in the load and through
the generator is small. Since small current means that a small magnetic field is
set up by the field poles, only a small voltage is induced in the armature.

If the resistance of the load decreases, the load current increases. Under this 
condition, more current flows through the field. This increases the magnetic field
and increases the output voltage.

A [series-wound DC generator characteristic](https://studyelectrical.com/2014/08/characteristics-of-series-wound-dc-generator.html)
shows that the output voltage varies with load current. This is undesirable in most
applications. For this reason, this type of generator is rarely used in everyday
practice.

### 2. DC Shunt Generator

In a shunt generator, **the field winding is connected in parallel with the armature
winding** so that the terminal voltage of the generator is applied across it.

The shunt field winding has many turns of fine wire having high resistance. Therefore,
only a part of armature current flows through shunt field winding and the rest flows
through the load. Also, read the [characteristics of a shunt generator](https://studyelectrical.com/2014/08/characteristics-of-shunt-generator.html).

The figure below shows the connections of a shunt-wound generator.

[⌊Shunt Wound Type of DC Generator⌉⌊Shunt Wound Type of DC Generator⌉[

Shunt Wound Type of DC Generator

Shunt field current, Ish = V/Rsh

 Armature current, Ia = I_(L) + Ish

 Terminal voltage, V = Eg – IaRa

 Power developed in armature = EgIa

 Power delivered to load = VI_(L)

Current in the field windings of a shunt-wound generator is independent of the load
current (currents in parallel branches are independent of each other). Since field
current, and therefore field strength, is not affected by load current, the output
voltage remains more nearly constant than does the output voltage of the series-
wound generator.

In actual use, the output voltage in a DC shunt-wound generator varies inversely
as load current varies. The output voltage decreases as load current increases because
of the voltage drop across the armature resistance increases (E = IR).

In a series-wound generator, the output voltage varies directly with load current.
In the shunt-wound generator, the **output voltage varies inversely with load current**.

A combination of the two types can overcome the disadvantages of both. This combination
of windings is called the compound wound DC generator.

### 3. DC Compound Generator

In a compound-wound generator, **there are two sets of field windings on each pole–
one is in series and the other in parallel with the armature**. 

In the compound-wound generator when load current increases, the armature voltage
decreases just as in the shunt-wound generator. This causes the voltage applied 
to the shunt-field winding to decrease, which results in a decrease in the magnetic
field.

This same increase in load current, since it flows through the series winding, causes
an increase in the magnetic field produced by that winding.

By proportioning the two fields so that the decrease in the shunt field is just 
compensated by the increase in the series field, the **output voltage remains constant**.

As you can see in [compound wound generator characteristics](https://studyelectrical.com/2014/08/characteristics-of-dc-compound-generator.html),
by proportioning the effects of the two fields (series and shunt), a compound wound
generator provides a constant output voltage under varying load conditions.

A compound-wound generator may be:

 1. **Short Shunt Compound DC Generator**
 2. **Long Shunt Compound DC Generator**
 3. [⌊Compound DC Generator ⌉⌊Compound DC Generator ⌉[
 4. (i) Short Shunt Compound DC Generator (ii) Long Shunt Compound DC Generator

Short Shunt compound dc generator is in which only shunt field winding is in parallel
with the armature winding.

Long Shunt compound dc generator is in which shunt field winding is in parallel 
with both series field and armature winding.

#### **3.1. Long shunt Compound Generator**

Series field current, Ise = Ia = I_(L) + Ish

Shunt field current, Ish = V/Rsh

Terminal voltage, V = Eg – Ia(Ra + Rse)

The power developed in armature = EgI

Power delivered to load = VI_(L)

#### **3.2 Short Shunt Compound Generator**

Series field current, Ise = I_(L) 

Shunt field current, 

Terminal voltage, V = Eg – IaRa – IseRse 

Power developed in armature = EgIa 

Power delivered to load = VI_(L)

In a compound generator, the major portion of excitation is usually supplied by 
the shunt field. The shunt field is slightly weaker and the series field is considerably
weaker than those of the corresponding machine in which the entire excitation is
produced by a single shunt or a single series winding.

Compound wound generators are of two types, known as **cumulative wound and differential
wound generators**.

In cumulative wound generators the series field assists the shunt field, whereas,
in differential wound generators, series field opposes the shunt field.

Read:  [Working Principle of Alternators](https://studyelectrical.com/2015/12/working-principle-of-alternator.html)

### Related posts:

No related posts.