# Characteristics of DC Shunt Generator

- Link: https://studyelectrical.com/2014/08/characteristics-of-shunt-generator.html
- Published: 2014-08-12T04:43:00+00:00
- Author: 

In this article, you will learn the characteristics of a dc shunt generator. A shunt
generator is a [type of dc generator](https://studyelectrical.com/2014/08/types-of-dc-generators.html)
in which the field winding is connected in parallel with the armature winding so
that the terminal voltage of the generator is applied across it. 

The shunt field winding has many turns of fine wire having high resistance. Therefore,
only a part of armature current flows through shunt field winding and the rest flows
through the load.

![DC Shunt Generator Connection Diagram](https://studyelectrical.com/wp-content/
uploads/2014/08/DC-Shunt-Generator-Connection-Diagram.png)

DC Shunt Generator Connection Diagram

The figure shows the connections of a shunt-wound generator. The armature current
I_(a) splits up into two parts; a small fraction Ish flowing through shunt field
winding while the major part IL goes to the external load.

### Open circuit characteristic

The Open circuit characteristic (OCC) of a shunt generator is similar in shape to
that of a series generator as shown in the figure below.

![Open Circuit Chatacteristics of DC Shunt Generator](https://studyelectrical.com/
wp-content/uploads/2014/08/Open-Circuit-Chatacteristics-of-DC-Shunt-Generator-.png)

Open Circuit Chatacteristics of DC Shunt Generator

The line OA represents the shunt field circuit resistance. When the generator is
run at normal speed, it will build up a voltage OM.

At no-load, the terminal voltage of the generator will be constant (= OM) represented
by the horizontal dotted line MC.

### Internal characteristic

When the generator is loaded, flux per pole is reduced due to armature reaction.

Therefore, e.m.f. E generated on load is less than the e.m.f. generated at no load.

As a result, the internal characteristic (E/Ia) drops down slightly as shown in 
Fig (ii).

  |  [⌊preview file+(5)⌉](http://3.bp.blogspot.com/-VtQlMSyiIG4/U-mTGSiGdGI/AAAAAAAABGc/ByboIlozbmU/s1600/preview_file+(5).png) |  
 |  Characteristics of Shunt Generator |

### External or Load characteristic

Curve 2 shows the external characteristic of a shunt generator.

It gives the relation between terminal voltage V and loads current IL.

V = E – IaRa = E – (IL + Ish)Ra

 

Therefore, external characteristic curve will lie below the internal characteristic
curve by an amount equal to drop in the armature circuit [i.e., (IL + Ish)Ra]as 
shown in Fig (ii).

Note. It may be seen from the external characteristic that the change in terminal
voltage from no-load to full load is small. The terminal voltage can always be maintained
constant by adjusting the field rheostat R automatically.

### Related posts:

No related posts.