# Split Phase and Capacitor Start Induction Motors

- Link: https://studyelectrical.com/2014/05/making-single-phase-induction-motor-self-starting.html
- Published: 2014-05-15T13:39:00+00:00
- Author: 

Before reading Split Phase and Capacitor Start Induction Motors, please read the
previous article, [Why a Single Phase Induction Motor is not Self Starting?](http://www.studyelectrical.com/2014/05/single-phase-induction-motor.html)

### Making a Single Phase Induction Motor Self Starting

As discussed in the previous article single-phase induction motors are not self-
starting. It is because a single-phase supply cannot produce a rotating magnetic
field. But we can create a rotating magnetic field by a two-phase construction.

So simply we can say _in order to **make a single-phase induction motor self-starting**,
we have to temporarily convert it into a two-phase motor during its starting period.
__

[⌊Auxiliary Winding and Main Winding⌉⌊Auxiliary Winding and Main Winding⌉[

Auxiliary Winding and Main Winding

For this purpose, the stator of the single-phase induction motor is provided with
an extra winding known as _Starting or Auxillary Winding_ in addition to the _Main
or Running Winding_. The two winding are 90 degrees electrically displaced and are
connected in parallel across the single-phase supply.

![Main Winding and Starting Winding](http://2.bp.blogspot.com/-b9GqV-oQNzw/U3LjQxUwIPI/
AAAAAAAAA2k/ccaUMYvNHhk/s1600/WP_20140508_11_36_38_Pro.jpg "Main Winding and Starting
Winding")

Main Winding and Starting Winding of a Single Phase Induction Motor

It is so arranged that the phase difference between the currents in two stator windings(
main and running windings ) is very large ( ideal value is 90 degrees). Hence the
motor behaves like a two-phase motor. These two currents produce a revolving flux
and hence make the motor self-starting.

The phase difference between the currents in the main winding and running winding
can be obtained through different methods. The phase shift can be achieved by connecting
a _resistance, [inductance](https://studyelectrical.com/2019/11/inductors-inductance-working-unit-function-types-uses.html)
or [capacitance](https://studyelectrical.com/2019/10/capacitance-working-unit-types-specification.html)
in series with the starting winding_. 

## Crating Phase difference between two windings

### Split Phase Induction Motor

In a split-phase machine, the main-winding has low resistance but high reactance
whereas the starting winding has a high resistance but low reactance.

[⌊Split Phase Motor and Phasor Diagram⌉⌊Split Phase Motor and Phasor Diagram⌉[

Split Phase Motor and Phasor Diagram

The resistance of the starting winding may be increased either by connecting a high
resistance R in series with it or by choosing a high-resistance fine copper wire
for winding purposes. 

Hence, as shown in Fig (b), the current I_(s) drawn by the starting winding lags
behind the applied voltage by a small angle whereas current I_(m) taken by the main
winding lags behind V by a very large angle. The phase angle between I_(s) and I_(
m) is made as large as possible because the starting torque of a split-phase motor
is proportional to sin α.

A centrifugal switch S is connected in series with the starting winding and is located
inside the motor. Its function is to automatically disconnect the starting winding
from the supply when the motor has reached 70 to 80 percent of its full load speed.

The centrifugal switch is necessary because the auxiliary winding cannot support
high currents for more than a few seconds without being damaged because it is made
of fine wire. In case of a capacitor start motor its is necessary because most motors
use a cheap [electrolytic capacitor](https://studyelectrical.com/2016/12/different-types-classification-of-capacitors.html)
that can only carry a.c current for a short period of time.

In the case of split-phase motors that are hermetically sealed in refrigeration 
units, instead of an internally mounted centrifugal switch, an electromagnetic type
of relay is used.

As shown in figure, the relay coil is connected in series with main winding and 
the pair of contacts which are normally open, is included in the starting winding.
During the starting period when I_(m) is large, relay contacts close thereby allowing
I_(s) to flow and the motor starts as usual. After motor speeds up to 75 percent
of full-load speed, I_(m) drops to value that is low enough to cause the contacts
to open.

These motors are often used in preference to the costlier capacitor-start motors.

Typical applications of split-phase motors are fans and blowers, centrifugal pumps
and separators, washing machines, small machine tools, duplicating machines, domestic
refrigerators, and oil burners, etc. Commonly available sizes range from 1/20 to
1/3 h.p. (40 to 250 W) with speeds ranging from 3,450 to 865 r.p.m.

The direction of rotation of such motors can be reversed by reversing the connections
of one of the two stator windings (riot both). For this purpose, the four leads 
are brought outside the frame. As seen from the figure, the connections of the starting
winding have been reversed.

The speed regulation of standard split-phase motors is nearly the same as of the
3-phase motors. Their speed varies about 2 to 5% between no load and full- load’
For this reason such motors are usually regarded as practically constant-speed motors.

Read: [Shaded Pole Induction Motor](https://studyelectrical.com/2016/02/shaded-pole-induction-motors-working-construction.html)

### Capacitor Start Induction run motors

In these motors, the necessary phase difference between I_(s) and I_(m) is produced
by connecting a capacitor in series with the starting winding as shown in Fig. The
capacitor is generally of the electrolytic type and is usually mounted on the outside
of the motor as a separate unit.

The capacitor is designed for extremely short-duty service and is guaranteed for
not more than 20 periods of operation per hour, each period not to exceed 3 seconds.
When the motor reaches about 75 percent of fulls speed, the centrifugal switch S
opens and cuts out both the starting winding and the capacitor from the supply, 
thus leaving only the running winding across the lines.

[⌊Capacitor-start Induction run motors⌉⌊Capacitor-start Induction run motors⌉[

Capacitor-start Induction run motors

As shown in Fig, current I_(m) drawn by the main winding lags the supply voltage
V by a large angle whereas I_(s) leads V by a certain angle. The two currents are
out of phase with each other by about 80° (for a 200-W 50-Hz motor) as compared 
to nearly 30 degrees for a split phase motor. Their resultant current I is small
and is almost in phase with V as shown in figure. 

Since the torque developed by a split-phase motor is proportional to the sine of
the angle between I_(s )and I_(m), it is obvious that the increase in the angle (
from 30 to 80 ) alone increases the starting torque to nearly twice the value developed
by a standard split-phase induction motor. Other improvements in motor design have
made it possible to increase the starting torque to a value as high as 350 to 450
percent.